ADR-0004: Tables are typed columns

Status: Accepted (one table per frame is proposed)
Date: 2026-11-21
Deciders: Format author

Context

Four parts of a book are tables: metadata (key, value), the resource list, the table of contents and the heading anchors. They are read at every open and can have thousands of rows. An OpenZL frame can carry several typed inputs (integers of a fixed width, strings with lengths) and returns them with their types.

Decision

Each table is one frame. Each column is one typed input, in a fixed order. Later minor versions add columns only at the end, and readers ignore columns they do not know.

Options considered

DimensionA: typed columns, one table per frameB: JSON or TOML in a serial frameC: typed columns, all tables in one frame
Reader complexityNo parser; slices of integers and stringsNeeds a text parser and a schema layerSame as A
File size849 B for a 120-row contents table957 B for the same tableSaves about 76 B per merged table
CompatibilityAny OpenZL decoder returns the columnsAny tool reads the textSame as A
EvolutionAppend columns per tableAdd keys freelyAppending to one table renumbers the others
InspectabilityNeeds a dump toolHuman-readable after decodingNeeds a dump tool

Chosen: A.

Trade-off analysis

  • The size difference between A and B is small. The deciding factor is the parser: columns need none, which keeps the container layer small and usable without the standard library.
  • B is easier to inspect and to extend with nested values. Flat key/value rows cover the metadata needed so far.
  • C saves a few hundred bytes per book and makes column positions global: no table could grow without shifting another. One frame per table keeps each table's positions private.

Consequences

  • Easier: zero-dependency readers; large tables stay compact (a 100,000-row resource table measured 362 KB and decoded in under 3 ms).
  • Harder: no nested values; a debugging tool is needed to look inside.
  • Harder: column order is fixed forever within a major version.
  • To revisit: nested metadata, if a use case needs more than key/value rows.

Action items

  1. Define table readers and builders in mbook.
  2. Reject a table whose columns differ in row count, type or width.
  3. Add a dump command that prints tables as text.